I want to buy a new Glow Worm 24cxi condensing combi. To keep costs
down, I want to get all the pipework ready before a CORGI plumber commissions the boiler. The manufacturer states that the central heating pipe and return pipe should be 22mm. All the pipework on my existing central heating system is 15mm. I read on several internet articles that to ease the load on the pump, the central heating loop should be fitted with 22mm pipes, and each radiator should be connected to the main loop with 15mm pipes. I will have 9 radiators in total (about 42,000 BTU's output). Does anyone know the pro's and cons of fitting 22mm pipes for the main heating loop rather than keeping the existing 15mm pipes? |
#3
![]() |
|||
|
|||
![]() |
#4
![]() |
|||
|
|||
![]()
Another thing you might want to look at is whether the syetem is plumbed
in such a way that you can split it into 2 sections and just run 22 to the point where they seperate. Mine was already like that. It had 15mm upstairs and 15mm downstairs, joining at a big T into the 22mm run to the boiler. As this occured near the understairs cupboard, I took the liberty of inserting a couple of zone valves at the splitting point and converting the Y-Plan to S-Plan Plus. Christian. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Shower cable in a copper pipe ?? | UK diy | |||
Saniflow : Coupling copper pipe to soil stack | UK diy | |||
Saniflow : Coupling copper pipe to soil stack | UK diy | |||
I LOVE Speedfit! | UK diy |