Hi
After removing a radiator and capping the ends, I have a prob on my combi Glow worm 80e boiler. The boiler sounds like its starting when you open a tap, but then after about 10secs, the lockout light comes on. I drained the CH system before I removed the rad and afterwards,I bled all the rads and refilled the system thru the filling loop.The pressure is 2.5 on the boiler. Surely , this is an air/pressure issue? , but I cant find any answers. Many thanks to anyone who can help |
#2
![]() |
|||
|
|||
![]() "heinzy" wrote in message oups.com... Hi After removing a radiator and capping the ends, I have a prob on my combi Glow worm 80e boiler. The boiler sounds like its starting when you open a tap, but then after about 10secs, the lockout light comes on. I drained the CH system before I removed the rad and afterwards,I bled all the rads and refilled the system thru the filling loop.The pressure is 2.5 on the boiler. Surely , this is an air/pressure issue? , but I cant find any answers. Many thanks to anyone who can help Did you also bleed the boiler pipework? If the boiler is above the height of the radiators, then the plumber must have given a point on the pipework at the boiler to bleed up to above the boiler heat exchange unit. |
#3
![]() |
|||
|
|||
![]()
On Sat, 25 Jun 2005 09:19:06 -0700, heinzy wrote:
Hi After removing a radiator and capping the ends, I have a prob on my combi Glow worm 80e boiler. The boiler sounds like its starting when you open a tap, but then after about 10secs, the lockout light comes on. I drained the CH system before I removed the rad and afterwards,I bled all the rads and refilled the system thru the filling loop.The pressure is 2.5 on the boiler. Surely , this is an air/pressure issue? , but I cant find any answers. Many thanks to anyone who can help See the Sealed CH FAQ. Most likely the auto air vent in the boiler is closed or defective. If you get that to work then the pressure may come down to something more reasonable. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Glow worm combi low pressure pressure | UK diy | |||
Regulations regarding cupboard space around a glow worm boiler? | UK diy | |||
glow worm boiler leaked, water damaged the floor and kitchen units. | UK diy | |||
Glow worm boiler problem | UK diy | |||
Is a Glow Worm 18HXI boiler any good? | UK diy |