Hello everyone.
I am an electrician in Ireland, and came across a problem a few days ago. I was investigating why a motor of a washing machine in a commercial laundry would not spin correctly and found the cables going from the tacho generator to the control electronic were causing the problem, I rerouted the cables and found all worked ok. I suspect some form of mutual inductance, the tacho cables only carry a small voltage, but was in a loom with many main voltage cables, Did anyone ever come across a similar problem ? If so what is the best way of identifying the problem, would an oscilloscope be required. Even though I know I sorted out the problem I would like to know the best way of testing for this problem . Thank you for all your help Seamus |
#2
![]() |
|||
|
|||
![]()
seamus wrote:
I am an electrician in Ireland, and came across a problem a few days ago. I was investigating why a motor of a washing machine in a commercial laundry would not spin correctly and found the cables going from the tacho generator to the control electronic were causing the problem, I rerouted the cables and found all worked ok. I suspect some form of mutual inductance, the tacho cables only carry a small voltage, but was in a loom with many main voltage cables, Did anyone ever come across a similar problem ? If so what is the best way of identifying the problem, would an oscilloscope be required. Even though I know I sorted out the problem I would like to know the best way of testing for this problem . Sounds to me like your experience, which made you suspicious of lead dress as a possibility, was the best troubleshooting tool for that job. A 'scope might have shown you noise on the tach wires, but might not have helped you determine its source. -- All relevant people are pertinent. All rude people are impertinent. Therefore, no rude people are relevant. -- Solomon W. Golomb |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Quick Change TP problem | Metalworking | |||
jointer problem | Woodworking | |||
Boiler Problem Gradually Getting Worse | UK diy | |||
Problem with JET Supersaw problem | Woodworking | |||
Sears air compressor starting problem | Woodworking |