![]() |
|
Seeking "Split Ring" Compression Fitting Spanner
I need a spanner like this:
http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D |
Seeking "Split Ring" Compression Fitting Spanner
On Sat, 2 Jan 2010 17:10:10 -0000, "Vortex5"
wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D Err...I'm guessing you don't have a TS near you then ? Motor Factors or Car Accessory shops/Halfords might have open ended Spanners/Ring Keys in those sizes which is more likely what they will know them as .Problem might be in getting one with the two sizes on the one spanner . |
Seeking "Split Ring" Compression Fitting Spanner
Usenet Nutter wrote:
On Sat, 2 Jan 2010 17:10:10 -0000, "Vortex5" wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D Err...I'm guessing you don't have a TS near you then ? Motor Factors or Car Accessory shops/Halfords might have open ended Spanners/Ring Keys in those sizes which is more likely what they will know them as .Problem might be in getting one with the two sizes on the one spanner . This is a job for an ordinary or ring spanner and an ANGLE GRINDER. |
Seeking "Split Ring" Compression Fitting Spanner
The Natural Philosopher wrote:
Usenet Nutter wrote: On Sat, 2 Jan 2010 17:10:10 -0000, "Vortex5" wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D Err...I'm guessing you don't have a TS near you then ? Motor Factors or Car Accessory shops/Halfords might have open ended Spanners/Ring Keys in those sizes which is more likely what they will know them as .Problem might be in getting one with the two sizes on the one spanner . This is a job for an ordinary or ring spanner and an ANGLE GRINDER. You swine, you beat me to it.... :o) |
Seeking "Split Ring" Compression Fitting Spanner
The Natural Philosopher wrote:
Usenet Nutter wrote: On Sat, 2 Jan 2010 17:10:10 -0000, "Vortex5" wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D Err...I'm guessing you don't have a TS near you then ? Motor Factors or Car Accessory shops/Halfords might have open ended Spanners/Ring Keys in those sizes which is more likely what they will know them as .Problem might be in getting one with the two sizes on the one spanner . This is a job for an ordinary or ring spanner and an ANGLE GRINDER. First one of the year, wll done that man! -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5 wrote:
I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5
wibbled on Saturday 02 January 2010 17:10 I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D If you are anywhere near Robertsbridge, East Sussex, you're welcome to borrow mine (seriously, email addy valid). But no, I haven't seen them in B&Q or Homobase or Wickes. -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
The Medway Handyman
wibbled on Saturday 02 January 2010 18:06 Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! Beware. They only fit a certain selection of nuts. They don't fit 15mm nuts on Peglar full bore valves - those nuts are bigger. For other jobs, I use a pair of slimline high quality adjustable spanners. -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
"Tim W" wrote in message ... Vortex5 wibbled on Saturday 02 January 2010 17:10 I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D If you are anywhere near Robertsbridge, East Sussex, you're welcome to borrow mine (seriously, email addy valid). But no, I haven't seen them in B&Q or Homobase or Wickes. -- Tim Watts This space intentionally left blank... Tim, Thanks for the kind offer. Immediate pressure is off now and I have ordered one. D |
Seeking "Split Ring" Compression Fitting Spanner
"The Medway Handyman" wrote in message m... Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". D |
Seeking "Split Ring" Compression Fitting Spanner
The Natural Philosopher wrote:
Usenet Nutter wrote: On Sat, 2 Jan 2010 17:10:10 -0000, "Vortex5" wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? D Err...I'm guessing you don't have a TS near you then ? Motor Factors or Car Accessory shops/Halfords might have open ended Spanners/Ring Keys in those sizes which is more likely what they will know them as .Problem might be in getting one with the two sizes on the one spanner . This is a job for an ordinary or ring spanner and an ANGLE GRINDER. Spoken like a true pro :-) Looks like the angle grinder has survived into 2010 then. That is the second called for use of it in DIY :-) Dave |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5 wrote:
"The Medway Handyman" wrote in message m... Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". Nice job that. -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
Seeking "Split Ring" Compression Fitting Spanner
The Medway Handyman
wibbled on Saturday 02 January 2010 23:08 For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". Nice job that. Seconded - nothing like a bit of neatly done copper. -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember The Natural Philosopher saying something like: This is a job for an ordinary or ring spanner and an ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5 wrote:
"The Medway Handyman" wrote in message m... Vortex5 wrote: "The Medway Handyman" wrote in message m... Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". Nice job that. -- Dave - The Medway Handyman www.medwayhandyman.co.uk Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
Seeking "Split Ring" Compression Fitting Spanner
"The Medway Handyman" wrote in message om... Vortex5 wrote: "The Medway Handyman" wrote in message m... Vortex5 wrote: "The Medway Handyman" wrote in message m... Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". Nice job that. -- Dave - The Medway Handyman www.medwayhandyman.co.uk Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? Bends. Looks a very good job. Congrats. |
Seeking "Split Ring" Compression Fitting Spanner
Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? -- Dave - The Medway Handyman www.medwayhandyman.co.uk Bends. Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. This won't be 100% true because the 90 degree boiler primary corner will need to use solder fittings...I have no 28mm bender (yet) D |
Seeking "Split Ring" Compression Fitting Spanner
"Vortex5" wrote in message ... "The Medway Handyman" wrote in message m... Vortex5 wrote: "The Medway Handyman" wrote in message m... Vortex5 wrote: I need a spanner like this: http://tinyurl.com/y9wa57q Problem is I would like it this weekend! Can anybody tell me if any of the "sheds" sell them, please? Don't know, but they look really useful - I'm going to order one! -- Dave - The Medway Handyman www.medwayhandyman.co.uk For the record I am in the process of implementing a major domestic heating upgrade (thermal store) and have used lots of those nice interlocking pipe clips that allow you to run parallel pipes very close to one another. Problem is that this clipping technology looks great but makes any compression joint utterly inaccessible. Example he http://home.btconnect.com/vortex/access.jpg Hence the need for one of these funky spanners. Today's leak was entirely due to incompetence on my part but now I want to check every nut before "going live". Nice job that. -- Dave - The Medway Handyman www.medwayhandyman.co.uk Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Unfortunately fannying about with heating systems in frosty weather is potentially very disruptive and unpopular with the family.....hence the Hep20 lashup to keep the house warm. Next stage is to remove all the old controls and plumbing (the white bits) reroute the boiler connections, slide in and connect the thermal store. The primary circuit will ultimately be about 600 litres capacity.....and I really do not want to have to drain it down in the worst case scenario to fix a leak, so I need to take my time. If I had one of these spanners I could potentially have finished today....but will have to defer a week because I have a "proper" job to go to tomorrow. Ho hum. D It looks fine is is very neat.Well done Can I ask why you dislike soldered joints? I prefer them over a compression joint anyday. Adam |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5 wrote:
Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? -- Dave - The Medway Handyman www.medwayhandyman.co.uk Bends. Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. This won't be 100% true because the 90 degree boiler primary corner will need to use solder fittings...I have no 28mm bender (yet) D BTW, could you let me know what the spanner is like when it arrives? -- Dave - The Medway Handyman www.medwayhandyman.co.uk |
Seeking "Split Ring" Compression Fitting Spanner
Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Unfortunately fannying about with heating systems in frosty weather is potentially very disruptive and unpopular with the family.....hence the Hep20 lashup to keep the house warm. Next stage is to remove all the old controls and plumbing (the white bits) reroute the boiler connections, slide in and connect the thermal store. The primary circuit will ultimately be about 600 litres capacity.....and I really do not want to have to drain it down in the worst case scenario to fix a leak, so I need to take my time. If I had one of these spanners I could potentially have finished today....but will have to defer a week because I have a "proper" job to go to tomorrow. Ho hum. D It looks fine is is very neat.Well done Can I ask why you dislike soldered joints? I prefer them over a compression joint anyday. Adam Actually there are quite a few solder joints, you just can't see them! No special deliberate strategy, just convenience. I've intentionally used compression joints in any location where future "tweaking" may be necessary D |
Seeking "Split Ring" Compression Fitting Spanner
"The Medway Handyman" wrote in message om... Vortex5 wrote: Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? -- Dave - The Medway Handyman www.medwayhandyman.co.uk Bends. Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. This won't be 100% true because the 90 degree boiler primary corner will need to use solder fittings...I have no 28mm bender (yet) D BTW, could you let me know what the spanner is like when it arrives? -- Dave - The Medway Handyman www.medwayhandyman.co.uk No problem sir. |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5
wibbled on Sunday 03 January 2010 15:59 Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. I was concerned about that with mine. Plan is to have the all pipes above the top of the unit - except for 4 straights going directly through a wall at the back corner - but those could be cut, and reinserted and rejointed clear of the tank, being straight... This makes sense for me as all the CH pipes need to head ceilingwards, the boiler is nearby and high level and the PlateX and pump assembly will be high up on the wall. I've gone to the trouble to cover the wall with floor to ceiling wood battens every 2 foot to make fixing the pipes simple. I still need to do a number of crossovers with vertical runs so it's going to get interesting. I think I will spend a week planning it on paper before I touch a pipe cutter! -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
The Medway Handyman
wibbled on Sunday 03 January 2010 16:50 BTW, could you let me know what the spanner is like when it arrives? I have that spanner. It's bloody good when it fits. It seems to fit "ordinary" compression joints (whatever that means) but not some types or Peglar valve. I would say it's worth having because it's very nice when you can use it. -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
"Tim W" wrote in message ... The Medway Handyman wibbled on Sunday 03 January 2010 16:50 BTW, could you let me know what the spanner is like when it arrives? I have that spanner. It's bloody good when it fits. It seems to fit "ordinary" compression joints (whatever that means) but not some types or Peglar valve. I would say it's worth having because it's very nice when you can use it. -- Tim Watts This space intentionally left blank... I wonder if I should have ordered 2? I can imagine an inline compression fitting, or isolation valve being a particular headache if you can't grip both ends. ....but actually I have a very thin jawed welding clamp (uses mole grip technology) with which I can improvise. D |
Seeking "Split Ring" Compression Fitting Spanner
"Tim W" wrote in message ... Vortex5 wibbled on Sunday 03 January 2010 15:59 Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. I was concerned about that with mine. Plan is to have the all pipes above the top of the unit - except for 4 straights going directly through a wall at the back corner - but those could be cut, and reinserted and rejointed clear of the tank, being straight... This makes sense for me as all the CH pipes need to head ceilingwards, the boiler is nearby and high level and the PlateX and pump assembly will be high up on the wall. I've gone to the trouble to cover the wall with floor to ceiling wood battens every 2 foot to make fixing the pipes simple. I still need to do a number of crossovers with vertical runs so it's going to get interesting. I think I will spend a week planning it on paper before I touch a pipe cutter! -- Tim Watts This space intentionally left blank... I am installing an XCEL 2009 from www.heatweb.com I have opted for the unvented system option, which introduces a variety of complications, not least finding a home for the 100 litre expansion vessel. All resolved though. Because the overall system volume will approach 600 litres it will need a lot of inhibitor. I have put check valves all over the place so I can deal with most leaks or problems without draining down the main store. I am however troubled by the thought of losing 50 quids worth of inhibitor If I have to drain down the whole thing! All being well should be commissioned within a week, and I intend to run it for a while with no new inhibitor to check integrity first. D |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5
wibbled on Sunday 03 January 2010 19:21 I am installing an XCEL 2009 from www.heatweb.com I have opted for the unvented system option, which introduces a variety of complications, not least finding a home for the 100 litre expansion vessel. All resolved though. I specc'd my own tank - a plain solar enabled jobbie with extra tappings all over. Vented system (I understand them) - but as luck would have it, there's a perfect location for the header tank (oversized oviously) in a bit of dead space in the attic above and along a bit - at least I should manage a gradient on the fill and expansion pipes to assist with filling and removeal of trapped air. That's the plan anyway :-o Because the overall system volume will approach 600 litres it will need a lot of inhibitor. Yes it will. Mine is 350l rough total estimate and that's already wallet burningly large amounts of inhibitor. I have put check valves all over the place so I can deal with most leaks or problems without draining down the main store. Ditto. I hope to fill the system once and flush, drain, fill with inhibitor and not drain it for the lifetime of the chemicals. I am however troubled by the thought of losing 50 quids worth of inhibitor If I have to drain down the whole thing! All being well should be commissioned within a week, and I intend to run it for a while with no new inhibitor to check integrity first. Indeed - I'd run it on plain water for a bit to check everything's happy and there are no leaks, air traps or any other little mods needed[1]. Week or two on plain shouldn't hurt it. It will ensure all the flux and crap is well washed out too, or translated, the flux is washed out and the crap is in the bottom of the store where it's not doing any harm. [1] I would like to put air seperators in as many places as practical (meaning high points, but where there isn't enough pump pressure to pump over into the expansion tank via the seperator). As my tank is below everything it feeds, it won't likely accumulate air appearing in other parts. Good luck - brave man doing it this time of year (or do you not have any CH anyway?). -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
Good luck - brave man doing it this time of year (or do you not have any CH anyway?). -- CH is working fine.....thankfully. Fortunately the new tank is in a different location to (what will be) the old tank so the transition should be very quick. A few hours. I have purchased a solar controller already (resol) and will get some tube collectors from www.navitron.org.uk in due course. Final step is a new boiler in the summer. Current Potterton is non-condensing. Have been looking at the Viessmann system boilers as an alternative. All up I hope to halve the gas bill. D |
Seeking "Split Ring" Compression Fitting Spanner
"Vortex5" wrote in message ... "Tim W" wrote in message ... Vortex5 wibbled on Sunday 03 January 2010 15:59 Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. I was concerned about that with mine. Plan is to have the all pipes above the top of the unit - except for 4 straights going directly through a wall at the back corner - but those could be cut, and reinserted and rejointed clear of the tank, being straight... This makes sense for me as all the CH pipes need to head ceilingwards, the boiler is nearby and high level and the PlateX and pump assembly will be high up on the wall. I've gone to the trouble to cover the wall with floor to ceiling wood battens every 2 foot to make fixing the pipes simple. I still need to do a number of crossovers with vertical runs so it's going to get interesting. I think I will spend a week planning it on paper before I touch a pipe cutter! -- Tim Watts This space intentionally left blank... I am installing an XCEL 2009 from www.heatweb.com I have opted for the unvented system option, which introduces a variety of complications, not least finding a home for the 100 litre expansion vessel. All resolved though. Because the overall system volume will approach 600 litres it will need a lot of inhibitor. I have put check valves all over the place so I can deal with most leaks or problems without draining down the main store. I am however troubled by the thought of losing 50 quids worth of inhibitor If I have to drain down the whole thing! All being well should be commissioned within a week, and I intend to run it for a while with no new inhibitor to check integrity first. Are you using the vented expansion vessel? Put in full bore valve as isolators to avoid losing the inhibitor. |
Seeking "Split Ring" Compression Fitting Spanner
I am installing an XCEL 2009 from www.heatweb.com I have opted for the unvented system option, which introduces a variety of complications, not least finding a home for the 100 litre expansion vessel. All resolved though. Because the overall system volume will approach 600 litres it will need a lot of inhibitor. I have put check valves all over the place so I can deal with most leaks or problems without draining down the main store. I am however troubled by the thought of losing 50 quids worth of inhibitor If I have to drain down the whole thing! All being well should be commissioned within a week, and I intend to run it for a while with no new inhibitor to check integrity first. Are you using the vented expansion vessel? Put in full bore valve as isolators to avoid losing the inhibitor. I've thought hard about this and will be installing a full bore valve at the main feed to the store. Whilst not strictly compliant, this will solve the problem. In any event the store has 2 pressure relief points (one by the expansion vessel and one at the top). I will also make sure the valve is disabled so it cannot be casually closed. |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5
wibbled on Monday 04 January 2010 06:30 I've thought hard about this and will be installing a full bore valve at the main feed to the store. Whilst not strictly compliant, this will solve the problem. In any event the store has 2 pressure relief points (one by the expansion vessel and one at the top). I will also make sure the valve is disabled so it cannot be casually closed. Why do you think it's not compliant - sounds fine to me. The expansion pipe at the top is serving the purpose perfectly. -- Tim Watts This space intentionally left blank... |
Seeking "Split Ring" Compression Fitting Spanner
"Tim W" wrote in message ... Vortex5 wibbled on Monday 04 January 2010 06:30 I've thought hard about this and will be installing a full bore valve at the main feed to the store. Whilst not strictly compliant, this will solve the problem. In any event the store has 2 pressure relief points (one by the expansion vessel and one at the top). I will also make sure the valve is disabled so it cannot be casually closed. Why do you think it's not compliant - sounds fine to me. The expansion pipe at the top is serving the purpose perfectly. -- Tim Watts This space intentionally left blank... I am going by DPS' own manual which has words to the effect: "The expansion relief valve must be connected directly to the feed input of the heatbank without the possibility of isolation" But hey rules are made for breaking....and there is another valve. D |
Seeking "Split Ring" Compression Fitting Spanner
Grimly Curmudgeon wrote:
We were somewhere around Barstow, on the edge of the desert, when the drugs began to take hold. I remember The Natural Philosopher saying something like: This is a job for an ordinary or ring spanner and an ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. |
Seeking "Split Ring" Compression Fitting Spanner
Vortex5 wrote:
Thanks, To many people it seems rather perverse but I love plumbing. Work in progress as of yesterday afternoon is he http://home.btconnect.com/vortex/wip.jpg Are all those bends in the corner actual bends or elbows? -- Dave - The Medway Handyman www.medwayhandyman.co.uk Bends. Thermal store will be pushed into that corner. My goal has been to have zero inaccessible joints. All joints are accessible. Its only a question of how much house you have to remove to access them. |
Seeking "Split Ring" Compression Fitting Spanner
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember The Natural Philosopher saying something like: This is a job for an ordinary or ring spanner and an ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. How little you know. |
Seeking "Split Ring" Compression Fitting Spanner
On Mon, 04 Jan 2010 11:14:03 +0000, The Natural Philosopher wrote:
Grimly Curmudgeon wrote: We were somewhere around Barstow, on the edge of the desert, when the drugs began to take hold. I remember The Natural Philosopher saying something like: This is a job for an ordinary or ring spanner and an ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. I'd agree with you: I've a ring spanner for 1/2" tail nuts that was made by cutting out a 16mm piece (sorry - not with an AG), sawing off the cut ring and welding it back on 90 deg. for getting under sinks etc. It's had a fair bit of force on it at times and is still in perfect condition. -- Peter. 2x4 - thick plank; 4x4 - two of 'em. |
Seeking "Split Ring" Compression Fitting Spanner
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember PeterC saying something like: ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. I'd agree with you: I've a ring spanner for 1/2" tail nuts that was made by cutting out a 16mm piece (sorry - not with an AG), sawing off the cut ring and welding it back on 90 deg. for getting under sinks etc. It's had a fair bit of force on it at times and is still in perfect condition. And what was the wall thickness and depth of this ring spanner to start with? I suspect it was a fairly hefty old piece. NP's assertion that it would be 'a **** spanner to begin with' is full of holes - then again, he talks much ****. Many of the high-quality slimline ring spanners wouldn't stand for this kind of treatment, but you'd tend to find the older low-tech, low-browed, material-instead-of-quality designs might, probably not for long though. Here's a clue - I have several Snap-On open brakeline spanners going back decades and without exception they are all hex (not 12-pointed) and heavy sidewalled to compensate for the open end. Aye, **** spanners indeed. |
Seeking "Split Ring" Compression Fitting Spanner
Grimly Curmudgeon wrote:
We were somewhere around Barstow, on the edge of the desert, when the drugs began to take hold. I remember PeterC saying something like: ANGLE GRINDER. Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. I'd agree with you: I've a ring spanner for 1/2" tail nuts that was made by cutting out a 16mm piece (sorry - not with an AG), sawing off the cut ring and welding it back on 90 deg. for getting under sinks etc. It's had a fair bit of force on it at times and is still in perfect condition. And what was the wall thickness and depth of this ring spanner to start with? I suspect it was a fairly hefty old piece. NP's assertion that it would be 'a **** spanner to begin with' is full of holes - then again, he talks much ****. Many of the high-quality slimline ring spanners wouldn't stand for this kind of treatment, but you'd tend to find the older low-tech, low-browed, material-instead-of-quality designs might, probably not for long though. Here's a clue - I have several Snap-On open brakeline spanners going back decades and without exception they are all hex (not 12-pointed) and heavy sidewalled to compensate for the open end. Aye, **** spanners indeed. Th day I put 100lb ft on a compression fitting is the day you can call me Drivel. You simply don't NEED that much. |
Seeking "Split Ring" Compression Fitting Spanner
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember The Natural Philosopher saying something like: Th day I put 100lb ft on a compression fitting is the day you can call me Drivel. You simply don't NEED that much. Who mentioned 100ft/lb? A bodgy cut-apart ring will open at much less than that. Go and service a nuke. |
Seeking "Split Ring" Compression Fitting Spanner
On Mon, 04 Jan 2010 14:01:57 +0000, Grimly Curmudgeon wrote:
Only for a clot. The wall strength of a cut ring spanner is ****. Then it was a **** spanner to start with. I'd agree with you: I've a ring spanner for 1/2" tail nuts that was made by cutting out a 16mm piece (sorry - not with an AG), sawing off the cut ring and welding it back on 90 deg. for getting under sinks etc. It's had a fair bit of force on it at times and is still in perfect condition. And what was the wall thickness and depth of this ring spanner to start with? I suspect it was a fairly hefty old piece. Third-world job: England, Bedford vanadium. Wall's about 2.5mm/1.5mm, 12-point. Obviously I use a lever through t'other end. -- Peter. 2x4 - thick plank; 4x4 - two of 'em. |
Seeking "Split Ring" Compression Fitting Spanner
We were somewhere around Barstow, on the edge of the desert, when the
drugs began to take hold. I remember PeterC saying something like: And what was the wall thickness and depth of this ring spanner to start with? I suspect it was a fairly hefty old piece. Third-world job: England, Bedford vanadium. Wall's about 2.5mm/1.5mm, 12-point. Obviously I use a lever through t'other end. Bugger. The exception that etc. I admit that Bedford vanadium spanners were tough old things, but I'd like to see that used day-in, day-out on taps and see how long it takes before the jaws spread. |
All times are GMT +1. The time now is 05:12 AM. |
|
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 DIYbanter