Bridge Rectifier
Im a novice and trying to understand the logics here. My monitor has the
120v AC line coming into a Full bridge rectifier(4 Diode set) with 3 .01 filter caps. Why do I get 183volts DC out the other side and not 120volts DC? If a picture is required let me know |
Bridge Rectifier
Why do I get 183volts DC out the other side and not 120volts DC?
Steve Lewinsky http://groups.google.com/groups?num=...oogle+S earch |
Bridge Rectifier
Typically the unloaded output voltage should be 1.414 * RMS input voltage in
your case 120 volts. Sounds like you have a little more than 120. "Steve Lewinsky" wrote in message le.rogers.com... Im a novice and trying to understand the logics here. My monitor has the 120v AC line coming into a Full bridge rectifier(4 Diode set) with 3 .01 filter caps. Why do I get 183volts DC out the other side and not 120volts DC? If a picture is required let me know |
Bridge Rectifier
"Steve Lewinsky" wrote in message le.rogers.com... Im a novice and trying to understand the logics here. My monitor has the 120v AC line coming into a Full bridge rectifier(4 Diode set) with 3 .01 filter caps. Why do I get 183volts DC out the other side and not 120volts DC? If a picture is required let me know The output of the bridge rectifier should go through some filtering that has large electrolytic capacitors. The unloaded voltage would be 1.414 * RMS or 1.414 * 120 = ~170 VDC. The fact that you are reading 183 VDC shows that there is no load on the power supply! Something has open circuited, causing a no load condition. |
Bridge Rectifier
"scada" wrote in message t... "Steve Lewinsky" wrote in message le.rogers.com... Im a novice and trying to understand the logics here. My monitor has the 120v AC line coming into a Full bridge rectifier(4 Diode set) with 3 .01 filter caps. Why do I get 183volts DC out the other side and not 120volts DC? If a picture is required let me know The output of the bridge rectifier should go through some filtering that has large electrolytic capacitors. The unloaded voltage would be 1.414 * RMS or 1.414 * 120 = ~170 VDC. The fact that you are reading 183 VDC shows that there is no load on the power supply! Something has open circuited, causing a no load condition. The ~170 volts should be the open circuit voltage. 183vdc can only be accounted for by the fact the input is more than 120 or measurements are incorrect. |