Default Water heater element control

The wiring is as you describe. Go to Home Depot and get a replacement
element for $10.

--- sam | Sci.Electronics.Repair FAQ Home Page: http://www.repairfaq.org/
Repair | Main Table of Contents: http://www.repairfaq.org/REPAIR/
+Lasers | Sam's Laser FAQ: http://www.repairfaq.org/sam/lasersam.htm
| Mirror Site Info: http://www.repairfaq.org/REPAIR/F_mirror.html

Important: The email address in this message header may no longer work. To
contact me, please use the feedback form on the S.E.R FAQ Web sites.




(WbSearch) writes:

By mistake I turned the power on to my water heater before the tank was full of
water and burned the upper element. I thought the lower element would provide
heat, but obviously at a lower rate. I found no power at the element. It
appears from the limited wiring diagram I have, that the upper thermostat
switch provides power to the upper element until it reaches the set
temperature, then provides power to the lower thermostat and element. Is that
correct? I needed to wire the lower thermostat to the upper element to get
heat last night until stores opened today and I could get a replacement.
I thought both elements were powered at once, but appears that is not the case.
The heater has what the supplier calls typical 2 element wiring.
My questions are 1) are indeed the elements powered as I described or am I
missing something?, and 2) is there a suggested temp. setting for the elements
if that is true, i.e. should the lower element be set at a higher temp then the
upper?
Thanks in advance.